SMA
Sunny Boy 6000U
6kW Grid Tie Inverter
Now
available in North America. Sunny Boy’s extensive track record in some of the
world’s most demanding markets has made it the favorite among PV professionals
everywhere. Over 250,000 Sunny Boy inverters have been installed throughout the
world. Superior design, rock-solid German engineering and exceptional real-world
efficiency have made Sunny Boy inverters the top choice for American solar
designers.
The Sunny Mini Central 6000
provides the advantages of a transformer inverter combined with all monitoring
and protection equipment (ENS) required for reliable operation of a PV-plant
without separate disconnection unit.
-
Exceptional
reliability, efficiency and energy capture ratio 5-year comprehensive warranty
-
Rugged stainless
steel outdoor enclosure standard
-
Easy to install
wall mount bracket system
-
Comprehensive
SMA communications and data collection options
-
SMA’s modular
commercial
inverter design is expandable to virtually any size system
The SB6000U is designed for
use with PV, fuel cell, wind-turbine, hydro-turbine and micro-turbine
technologies.
The SB6000U follows SMA’s
modular system design philosophy for utility, commercial and residential PV
installations from 6kW and up. Automatic sensing of the site utility voltage
makes installation trouble-free on almost any utility system. Just wire the
inverter into any 208, 277 or 240 VAC system, make one internal jumper setting
and the SB6000U does the rest.
The wide DC input voltage
range allows connection to almost any type or model of PV module. Proven
peak-power-point tracker results in maximum energy capture. The SB6000U uses the
same SMA communication accessories as every other inverter in the Sunny Boy
family. SMA offers a variety of hardware and software solutions from low cost
wireless monitoring, to complex data acquisition systems that integrate large
numbers of inverters with external sensors to networked PC’s and the internet.
Sunny Boy 6000U Technical
Specifications
Input Values (208V) |
|
|
Recommended max PV Power |
PPV |
6500 Wp
STC |
Max DC Power |
PDC, max |
5500 Wp
PTC |
DC
Input
Voltage Range |
VDC |
207 to 600 VDC |
MPP
Tracking Voltage Range |
VPV |
207 to 550 VDC |
PV Start Voltage |
VPV |
270 VDC |
Max input current |
IPV, max |
25 A |
DC Voltage ripple |
VPP |
< 5% |
DC Disconnectors |
|
Optional external DC Disconnect/Breaker |
Pole confusion protection |
|
Short Circuit diode |
Ground fault protection |
IDif |
> 1000 mA |
Input Values (240V) |
|
|
Recommended max PV Power |
PPV |
7500 Wp
STC |
Max DC Power |
PDC, max |
6300 Wp
PTC |
DC
Input
Voltage Range |
VDC |
234 to 600 VDC |
MPP
Tracking Voltage Range |
VPV |
234 to 550 VDC |
PV Start Voltage |
VPV |
300 VDC |
Max input current |
IPV, max |
25 A |
DC Voltage ripple |
VPP |
< 5% |
DC Disconnect |
|
Optional external DC Disconnect/Breaker |
Pole confusion protection |
|
Short Circuit diode |
Ground fault protection |
IDif |
> 1000 mA |
Input Values (277V) |
|
|
Recommended max PV Power |
PPV |
7500 Wp
STC |
Max DC Power |
PDC, max |
6300 Wp
PTC |
DC
Input
Voltage Range |
VDC |
234 to 600 VDC |
MPP
Tracking Voltage Range |
VPV |
234 to 550 VDC |
PV Start Voltage |
VPV |
300 VDC |
Max input current |
IPV, max |
25 A |
DC Voltage ripple |
VPP |
< 5% |
DC Disconnect |
|
Optional external DC Disconnect/Breaker |
Pole confusion protection |
|
Short Circuit diode |
Ground fault protection |
IDif |
> 1000 mA |
Output Values (208V) |
|
|
Max AC Power |
PAC |
5200 W |
Total Harmonic Distortion |
THDIAC |
< 4% (With KVgrid < 2% and PAC > 0.5 PACnom) |
Operating Range, Grid Voltage |
VAC |
183 V to 229 V |
Operating Range, Grid Frequency |
fAC |
59.3 Hz - 60.5 Hz |
Phase Shift (Ref. Fundamental) |
cos(phi) |
0° |
Output Values (240V) |
|
|
Max AC Power |
PAC |
6000 W |
Total Harmonic Distortion |
THDIAC |
< 4% (With KVgrid < 2% and PAC > 0.5 PACnom) |
Operating Range, Grid Voltage |
VAC |
211 V to 264 V |
Operating Range, Grid Frequency |
fAC |
59.3 Hz - 60.5 Hz |
Phase Shift (Ref. Fundamental) |
cos(phi) |
0° |
Output Values (277V) |
|
|
Max AC Power |
PAC |
6000 W |
Total Harmonic Distortion |
THDIAC |
< 4% (With KVgrid < 2% and PAC > 0.5 PACnom) |
Operating Range, Grid Voltage |
VAC |
244 V to 305 V |
Operating Range, Grid Frequency |
fAC |
59.3 Hz - 60.5 Hz |
Phase Shift (Ref. Fundamental) |
cos(phi) |
0° |
Output Protection |
|
|
Islanding Protection |
|
VAC; FAC designed to meet the requirements
of UL 1741 |
Ground Fault Protection |
|
IDIF; designed to mee the requirements of UL 1741 |
A C Disconnect |
|
External AC Breaker |
Short Circuit Protection |
|
Current Controlled |
Overvoltage Classification |
|
III |
Efficiency |
|
|
Peak Efficiency |
|
95 % (Rebate Efficiency) |
Power Consumption |
|
|
Internal consumption in operation |
|
< 7 W |
Internal consumption at night |
|
0.25 W |
American Standards |
|
|
Hardware Safety |
|
Designed to meet the requirements of UL 1741 |
Firmware Safely |
|
Designed to meet the requirements of UL 1998 |
Power Quality |
|
IEEE 519 |
Anti-Islanding |
|
IEEE 929 |
Electro-Magnetic Interference |
|
FCC Part 15 A & B |
Size and Weight |
|
|
Width |
|
430 mm (16.9 in) |
Height |
|
600 mm (23.6 in) |
Depth |
|
250 mm (9.8 in) |
Weight |
|
63 kg (139 lbs) |
Enclosure Ratings |
|
|
NEMA Rating |
|
NEMA 3R |
Ambient Conditions |
|
|
Ambient
Temperature
Range |
|
-13°F to +140°F or -25°C to +60°C |
Relative Humidity Level |
|
0 to 100% |
|