Surge Protection You Can Count
On!
MidNite Solar Surge Protection
Devices (SPD) are Type 2 device per UL1449 rev3, NEC 2011 Article 285 designed
for indoor and outdoor applications. Engineered for both AC and DC
electrical systems they provide protection to service panels, load centers and
electronic devices that are directly connected to a MidNite Surge Protection
Device.
Features:
Performance |
Surge Current Rating per Phase |
57kA |
Short Circuit Current Rating |
115kA |
T-MOVs |
8 |
Fusing |
Individually fused MOVs |
Thermal Fusing |
Yes |
Over current Fusing |
Yes |
Operating Frequency |
0 to 60 Hz |
Mechanical Description |
Enclosure |
Polycarbonate UL94V-0 |
Environmental Rating |
Type 4X |
Connection Method |
#12 AWG |
Weight |
1 lb. |
Mounting Method |
1/2” Conduit Knockout |
Operating Altitude |
Sea Level - 12,000’ (3,658 Meters) |
Storage Temp |
-40o F to +185o F (-40o C to +85o C) |
Operating Temp |
-40o F to +185o F (-40o C to +85o C) |
Diagnostics |
Blue status LED, one per leg |
|
Listings and Performance |
UL Standard for Safety, UL 1449 Surge Protective Devices-Third Edition
CSA C22.2 No. 8-M1986 Electromangetic Interference (EMI) Filters, Fourth
Edition |
With lightning you only get
one chance. so get the best!.
The SPD is offered in four
different voltages to maximize the required protection level. Protection is
achieved by reducing the clamping voltage to a safe level that your system can
sustain without damaging any electronics in the system. The MidNite SPD are
designed to clamp a 115,000 amp surge! Blue LED’s provide visual indication of
operation from a distance.
PART NO. |
MNSPD-115 |
MNSPD-300-AC |
MNSPD-300-DC |
MNSPD-600 |
Nominal Voltage |
0 to 90 VAC
0 to 115 VDC |
0 to 250 VAC |
0 to 300 VDC |
0 to 485 VAC
0 to 600 VDC |
MCOV |
180V (162-198) |
470V (423-517) |
470V (423-517) |
780V (702-858) |
Clamp Voltage @ 100A
Current 8/20 μs |
295V |
775V |
775V |
1290V |
Energy Absorption
In Joules |
1120 J (Full Device)
560 J (Each Section) |
3130 J (Full Device)
1560 J (Each Section) |
3130 J (Full Device)
1560 J (Each Section) |
4320 J (Full Device)
2160 J (Each Section) |
Suggested Placement |
Up to 90 VAC circuits,
12V, 24V, 48V DC
battery circuits |
120/240 VAC circuits |
Off-grid PV combiners
Charge controller inputs
up to 300VDC |
316V/480 VAC circuits
Grid-tie PV combiners
Grid-tie inverter input
Non-Isolated Inverters |
Diagnostic Blue LED |
MNSPD-115, MNSPD-300-AC and MNSPD-300-DC
LED indicates when voltage is present between L1+Ground and L2+Ground
MNSPD-600
LED indicates when voltage is present between L1+L2 (PV + PV-) |
Thermal Disconnector -
Internal Fuse |
Response time
<1 micro sec. |
Model No. |
Max Operating
Voltage |
Surge Current
per Phase |
Configuration |
MCOV |
SCCR |
VPR 600V/3kA
L_G |
MNSPD-115 |
90VAC/115VDC |
57kA |
1 O, 3-wire (2 Legs) |
180V L-N |
115kA |
330V |
MNSPD-300-AC |
250VAC |
57kA |
1 O, 3-wire (2 Legs) |
470V L-N |
115kA |
880V |
MNSPD-300-DC |
300VDC |
57kA |
1 O, 3-wire (2 Legs) |
470V L-N |
115kA |
880V |
MNSPD-600 |
485VAC/600VDC |
57kA |
1 O, 3-wire (2 Legs) |
780V L-N |
115kA |
1500V |
|