Fronius IG |
IG 2000 |
IG 3000 |
IG 2500-LV |
DC Input Data |
|
|
|
Recommend PV power (Wp) |
1500 -
2500 |
2500 -
3300 |
1800 -
3000 |
Max. DC input voltage |
500 V |
500 V |
500 V |
Operating DC voltage range |
150 -
450 V |
150 -
450 V |
150 -
450 V |
Max. usable DC input current |
13.6 A |
13.6 A |
13.6 A |
AC Output Data |
|
|
|
Max. Output power @ 40°C |
2000 W |
2700 W |
2350 W |
Nominal AC output voltage |
240 V |
240 V |
208 V |
Utility AC voltage range |
212 - 264 V (240 V+10%/-12%) |
183 - 227 V |
Maximum AC current |
8.35 A |
11.25 A |
11.25 A |
Max. utility back feed current |
0.0 A |
0.0 A |
0.0 A |
Frequency Range |
59.3 -
60.5 Hz (60 Hz nom) |
Total Harmonic Distortion THD |
<5% |
Power Factor (cos phi) |
1 |
General Data |
|
|
|
Max. Efficiency |
95.2% |
95.2% |
94.4% |
Consumption in stand-by |
< 0.15 W (night) |
Operational Consumptio |
7 W |
Enclosure |
NEMA 3R |
Size (l x w x h) |
18.8 x
16.5 x 8.8 inches (470 x 418 x 223 mm) |
Weight |
26 lbs (11.8 kg) |
Ambient Temperature Range |
-5 to
122 °F (-20 to +50 °C) |
Cooling |
controlled forced ventilation |
Integrated AC and DC disconnects |
standard
UL approved DC & AC disconnects |
Protections |
|
Ground fault protection |
Internal
GFDI, in accordance with UL 1741 |
DC reverse polarity |
Internal diode |
Islanding protection |
Internal, in accordance with UL 1741, IEEE 1547 |
Over temperature |
Output power derating |
Surge protection |
Internadl DC & AC protection to 6 kV |
Compliance |
|
Safety |
UL 1741 |
EMI |
FCC Part 15; Class A & B |
Anti-islandinig protection |
UL 1741,
IEEE 1547 |
Ground fault detector and interruptor |
Compliant with NEC Art. 690 requirements, UL 1741 |
Miscellaneous |
|
Max. AC over current protection |
Two-pole, 15 / 20 A circuit breaker |
AC wire sizing |
Use
maximum AWG 6 194 °F (90 °C) copper |
DC wire sizing |
Use maximum AWG 8 194 °F (90 °C) copper |
AC disconnect |
16 A |
DC disconnect |
25 A |
Warranty |
10 year
Premium Warranty is standard |