Fronius IG Plus |
10.0-1UNI |
11.4-1UNI |
11.4-3Delta |
12.0-3WYE277 |
Input |
|
Recommended PV-Power (Wp) |
8500-11500 |
9700-13100 |
9700-13100 |
10200-13800 |
MPPT-Voltage range |
230 - 500 V |
Max. Input voltage range |
600 V
(at 1000 W/m² 14°F (-10°C) in open circuit operation) |
Nominal Input Current |
27.6 A |
31.4 A |
31.4 A |
33.1 A |
Max. usable Input Current |
46.7 A |
53.3 A |
53.3 A |
56.1 A |
Admissible conductor size (DC) |
No. 14-6 AWG |
Output |
|
Nominal output power (PAC nom) |
9995 W |
11400 W |
11400 W |
12000 W |
Max. cont. output power
104°F (40°C) 208V/ 240V/ 277V |
9995 W |
11400 W |
11400 W |
12000 W |
Nominal AC output voltage |
208 V / 240 V / 277 V |
208 V / 240 V |
277 V |
Operating AC voltage range
208 V
240 V
277 V |
183 - 229 V (-12 / +10 %)
211 - 264 V (-12 / +10 %)
244 - 305 V (-12 / +10 %) |
Nominal output current
208 V
240 V
277 V |
48.1 A
41.7 A
36.2 A |
54.8 A
47.5 A
41.2 A |
31.6 A
27.4 A
n.a. |
n.a.
n.a.
14.4 A |
Max. output current
208 V
240 V
277 V |
54.6 A
47.4 A
40.9 A |
55.5 A
54.0 A
46.7 A |
32.0 A
31.2 A
n.a. |
n.a.
n.a.
16.4 A |
Admissible conductor size (AC) |
No. 14 - 4 AWG |
Max. continuous utility back feed current |
0 A |
Nominal frequency |
60 Hz |
Operating frequency range |
59.3 - 60.5 Hz |
Total harmonic distortion |
< 3 % |
Power factor |
1 |
General data |
|
Max. Efficiency |
96.20% |
CEC Efficiency
208 V
240 V
277 V |
95.0 %
95.5 %
96.0 % |
95.5 %
96.0 %
96.0 % |
95.5 %
96.0 %
n.a. |
n.a.
n.a.
96.0 % |
Consumption in standby (night) |
< 1 W |
Consumption during operation |
22 W |
Cooling |
Controlled forced ventilation, variable fan speed |
Enclosure Type |
NEMA 3R |
Unit Dimensions (W x H x D) |
17.1 x 48.1 x 9.6. in. |
Inverter Weight |
82 lbs. (37 kg) |
Wiring Compartment Weight |
26 lbs. (12 kg) |
Admissible ambient operating temperature |
-4 through 122°F
(-20 through + 50°C) |
Compliance |
UL 1741-2005, IEEE1547-2003, IEEE 1547.1, ANSI/IEEE C62.41, FCC Part 15 A&B,
NEC Article 690, C22. 2 No. 107.1-01 (Sept. 2001) |
Safety equipment |
|
|
|
|
Ground fault protection |
Internal GFDI (Ground Fault Detector/Interrupter); in accordance with UL
1741-2005 and NEC Art. 690 |
DC reverse polarity protection |
Internal diode |
Islanding protection |
Internal; in accordance with UL 1741-2005, IEEE 1547-2003 and NEC |
Over temperature |
Output power derating / active cooling |